  All console servers have the snmptrap daemon to send traps/notifications to remote SNMP 
servers on defined trigger events as detailed above. LES1408A, LES1416A, LES1432A, 
LES1448A, LES1308A, LES1316A, LES1332A, LES1348A, 
LES1208A-R2, LES1216A-R2, 
LES1232 and LES1248A-R2 console servers also embed the net-snmp
d daemon. It accepts 
SNMP requests from remote SNMP management servers and provides information on network 
interface, running processes, etc. (refer to Chapter 15.5—Modifying SNMP Configuration for 
more details). 
 
 7.5.4   Nagios alerts  
To notify the central Nagios server of Alerts, NSCA must be enabled under System: Nagios and Nagios 
must be enabled for each applicable host or port under Serial & Network: Network Hosts or Serial & 
Network: Serial Ports (refer to Chapter 10). 
 
7.6  Logging   
The console server can maintain log records of auto-response events and log records of all access and 
communications events (with the console server  and with the attached serial, network and power 
devices).  
A log of all system activity is also maintained by default, as is  a history of the status of any attached 
environmental monitors. 
7.6.1 
Log storage  
Before activating any Event, Serial, Network or UPS logging, you must specify where those logs are to be 
saved.  These records are stored off-server or in the console server USB flash memory. 