external modem via a serial cable to the DB9 port, and you can configure the second Ethernet 
port for broadband OoB access. 
Make sure you unplug the console server power before installing the modem. When it next boots, 
it will detect the modem and a PC Card Modem tab will appear under System -> Dial. 
The 
LES1508A, LES1408A, LES1416A, LES1432A, LES1448A, LES1308A, LES1316A, LES1332A, 
LES1348A, 
LES1108A, LES1116A, LES1132 and LES1148A models need to have an external 
modem attached via a serial cable to the DB9 port marked Local (located on the front of the unit). 
 
5.1.1  Configure Dial-In PPP 
To enable dial-in PPP access on the modem: 
 
 
Select the System: Dial menu option and the port to be configured (Serial DB9 Port or Internal 
Modem Port). 
  Check Enable Dial-In. 
Note 
The console server console/modem serial port is set by default to 115200 baud, No parity, 8 data 
bits and 1 stop bit, with software (Xon-Xoff) flow control enabled for the Serial DB9 Port and 9600 
baud for the Internal modem and PC Card Ports. When enabling OoB dial-in, we recommend that 
this be changed to 38,400 baud with Hardware Flow Control
 
Select the Baud Rate and Flow Control that will communicate with the modem. 
  Click Apply 
Note 
You can further configure the console/modem port (for example, to include modem init strings) by 
editing /etc/mgetty.config files as described in the Chapter 15—Advanced Configuration
. 