3.3  Mounting Dimensions 
The maximum space described in figures shows that the radius of the end effector is 60 
mm or less.    If the radius of the end effector exceeds 60 mm, define the radius as the 
distance to the outer edge of maximum space. 
If a camera or electromagnetic valve extends outside of the arm, set the maximum range 
including the space that they may reach. 
Be sure to allow for the following extra spaces in addition to the space required for 
mounting the Manipulator, Controller, and peripheral equipment. 
space for teaching 
space for maintenance and inspection 
(Ensure a space to open the rear side cover and the maintenance cover for 
maintenance.)  
space for cables 
The minimum bend radius of the power cable is 90 mm.    When installing the cable, be 
sure to maintain sufficient distance from obstacles.    In addition, leave enough space for 
other cables so that they are not bent forcibly. 
Ensure distance to the safeguard from the maximum motion range is more than 100 mm. 
 
G10-65** 
G10/G20-85**
G20-A0** 
Table Top Mounting 
Center of Joint#3
 
Maximum space
 
**** : G10/G20-85*S : 207.8
 G10/G20-85*C 
218.3
 
 
G10/G20-85* 
 
 
G10-65**
S C 
G20-A0**
Length of Arm #1 (mm) 
250 450 600 
Length of Arm #2 (mm) 
400 400 400 
Z: 0 to 
−360 207.8
(Motion range) 
212.4 207.8 
Z:
 −
 360 
∼ 
390 218.3
307 
Motion range of Joint #1 (degree) 
152 152 152 
Z: 0 to 
−360 
152.5
Motion range of Joint #2 (degree) 
152.5 
152.5 
Z: 
360 to 
390 
151 
152.5 
(Mechanical stop area) 
199.4 183.3 285.4 
Joint #1 angle to hit mechanical stop 
(degree) 
3 3 3 
Z: 0 to 
−360 
3.5 
Joint #2 angle to hit mechanical stop 
(degree) 
3.5 3.5 
Z: 
360 to 
390 
3.5 
 
)
NOTE
 
In the range Z: –360 to –390 mm, the area is limited by interference of the Manipulator body and the arm.