Honeywell MS5100 Series Manuale Utente

Pagina di 52
 
 
35
S
CANNER AND 
C
ABLE 
T
ERMINATIONS 
 
 
Cable Connector Configurations
 
 
 
RS232 PowerLink Cable, 
55-55000
x
-3 
 
Pin 
Function 
1 Shield 
Ground 
RS232 Transmit Output 
RS232 Receive Input 
DTR Input/Light Pen Source 
Power/Signal Ground  
Light Pen Data 
(DSR Out for -14 interfaces) 
7 CTS 
Input 
8 RTS 
Output 
9 +5VDC 
 
 
9-Pin D-Type Connector
 
 
Stand Alone Keyboard  
PowerLink Cable, 55-55020x-3 
 
Pin 
Function 
1 PC 
Data 
2 NC 
3 Power 
Ground 
+5VDC PC Power to KB 
5 PC 
Clock 
6 NC 
 
 
6-Pin Male Mini-DIN Connector
 
 
 
USB Communication 
55-55235
x
-N-3 or 55-55200
x
-N-3 
 
Pin 
Function 
1 PC 
+5V/V_USB 
2 D- 
3 D+ 
4 Ground 
Shield Shield 
 
 
Non-Locking, Type A
 
MLPN
 54-54214
x
-N-3 
 
 
Locking, Type A
 
 
MLPN
 54-54213
x
-N-3 or 
MLPN
 54-54214
x
-N-3