13 - 2
Replacing the Interface Cable
The standard interface cable is attached to the scanner with an 10-pin modular 
connector.  When properly seated, the connector is held in the 3800g scanner’s 
handle by a flexible retention tab.  The interface cable is designed to be field 
replaceable.
Order replacement cables from Honeywell or from an authorized distributor.
When ordering a replacement cable, specify the cable part number of the 
original interface cable.
To Replace the 3800g Interface Cable:
1. Turn the power to the host system 
OFF.
2. Disconnect the scanner’s cable from 
the terminal or computer.
3. Locate the small hole on the side of 
the scanner’s handle.  This is the 
cable release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the 
small hole and press in.  This 
depresses the retention tab, releasing 
the connector.  Pull the connector out 
while maintaining pressure on the 
paper clip, then remove the paper clip.
6. Replace with the new cable.  
Insert the connector into the opening 
and press firmly.  The connector is 
keyed to go in only one way, and will click into place.
Troubleshooting
The scanner automatically performs self-tests whenever you turn it on.  If your 
scanner is not functioning properly, review the following Troubleshooting Guide 
to try to isolate the problem.
Is the power on?  Is the aiming beam line on? 
If the aiming beam line isn’t illuminated, check that:
The cable is connected properly.
The host system power is on (if external power isn’t used).
The trigger works.
Cable
Release