Brocade Communications Systems 53-1002599-01 Manuale Utente

Pagina di 86
12
Brocade ICX 6650 Hardware Installation Guide
53-1002599-01
Installing the device in a rack or cabinet
2
CAUTION
Ensure that the device does not overload the power circuits, wiring, and over-current protection. 
To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all 
devices installed on the same circuit as the device. Compare this total with the rating limit for the 
circuit. The maximum ampere ratings are usually printed on the devices near the input power 
connectors.
CAUTION
Disconnect the power cord from all power sources to completely remove power from the device. 
CAUTION
If the installation requires a different power cord than the one supplied with the device, make 
sure you use a power cord displaying the mark of the safety agency that defines the regulations 
for power cords in your country. The mark is your assurance that the power cord can be used 
safely with the device.
Installing the device in a rack or cabinet
CAUTION
Make sure the rack or cabinet housing the device is adequately secured to prevent it from 
becoming unstable or falling over. 
NOTE
You need a #2 Phillips screwdriver for installation.
Before mounting the switch in a rack, pay particular attention to the following factors:
Temperature: Since the temperature within a rack assembly may be higher than the ambient 
room temperature, check that the rack-environment temperature is within the specified 
operating temperature range. (Refer to 
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should 
be given to supply connections other than direct connections to the mains.