2-2.    UNPACKING
Take care when moving the unit to prevent personal
injury or damage to the refrigeration system. The units
weigh between 400 (182 kg) and 580 lbs. (263 kg).
4.
Peel off any protective covering from exterior of the cabinet.
5.
Install the grids into unit.
6.
Your cold base is now ready for operation.
2-3.      ELECTRICAL
The cold base is available as a 120 VAC, 60 Hz. or 230VAC,
50Hz, single phase unit, both for domestic and international use.
The data plate, located beside the power cord, specifies the correct
electrical supply.  The cold bases are shipped with cord and plug,
and requires a grounded receptacle with a separate electrical line
protected by a fuse or circuit breaker of the proper rating.  Position
the unit so the power cord receptacle is accessible.
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors.
Refer to the table below for electrical ratings:
Model No.
Volts
Amps
Phase
Max. Fuse Size
CBC-103
120
8.1
1
15
CBC-103
230
5.8
1
15
CBC-104
120
8.1
1
15
CBC-104
230
7.3
1
15
CBC-105
120
9.5
1
15
CBC-105
230
7.5
1
15
CBC-106
120
9.5
1
15
CBC-106
230
7.5
1
15
CBC-107
120
9.5
1
15
CBC-107
230
7.7
1
15
          (Continued)
2-2
      303