ADIC 6-00025-01 Manuale Utente

Pagina di 132
Accessing Storage Devices
6-00025-01 Rev A
Connectivity and Media Preparation
1-7
Step 3.
Attempts to rebuild the directory for the volume: 
If the rebuild is successful, AMASS prints the 
following message to the system log: 
“E1036: 
DLT drive directory rebuilt on 
specified volume, in specified 
drive, in specified juke; volume 
left READONLY” 
AMASS marks the volume 
ACTIVE and updates the AMASS File System 
Database.
Otherwise, if the rebuild fails, AMASS prints the 
following message to the system log: 
“E1041: 
DLT drive directory NOT rebuilt on 
specified volume, in specified 
drive, in specified juke; volume 
left INACTIVE & READONLY!”
 AMASS 
leaves the volume INACTIVE, and reschedules 
any pending I/O requests to another volume. For 
further action, call AMASS technical support. 
Step 4.
If the rebuild is successful, use the AMASS 
volcomp
 command on the affected media. Retire 
the original media as “suspect.”
The 
volcomp
 command rewrites data on the source 
volume to a different volume in the same volume 
group. For more information on this command, refer 
to the Command Reference chapter in Managing the 
AMASS File System
.
Note
The status of the drive is not affected.