ADIC 6-00025-01 Manuale Utente

Pagina di 132
Accessing Storage Devices
6-00025-01 Rev A
Library List
2-7
The Scalar 1000 is taken OFFLINE-NOT READY perhaps 
because a door is open. The AMU automatically stops polling 
the AML/S whenever the library is offline.
Step 1.
Close the door, or take the appropriate steps to get 
the library to the ONLINE READY state.
Step 2.
Inventory the Scalar 1000 to ensure that only valid 
database information is uploaded.
Although the Scalar 1000 becomes operational, the 
AMU cannot initiate polling.
Step 3.
Run the 
HOME
 command from the AMU to establish 
communication with the Scalar 1000.
Step 4.
Activate polling by running the 
STATUS
 command 
with the appropriate option to select the correct 
robot. 
After the Scalar 1000 is online, the database is automatically 
uploaded. 
Note
If the Scalar 1000 is not inventoried in 
, the AMU database 
will contain invalid status information. Consequently, you must 
erase the AMU database and then recreate the database to clear 
this condition. (When changing the AMU configuration or database, 