Converting from 230 Volt to 460 Volt 
(Three Phase Only) 
Consult the wiring diagram inside the starter box 
cover. A diagram is also included on page 29 of 
this manual. The Jointer must comply with all 
local and national codes after being wired. 
1.  Remove the starter box cover and adjust the 
dial on the relay (see Figure 12) as close as 
possible to the amperage of the Jointer 
motor at 460V, as listed on the motor plate. 
2.  Move the fuse (Figure 12) from the 230V 
slot to the 460V slot. 
3.  Re-connect the incoming leads to the motor 
for 460 volt operation, as shown in the 
wiring diagram. 
4.  If using a plug, install a proper UL/CSA 
listed plug suitable for 460 volt operation.  
Three-Phase Test Run 
On the three-phase unit, after wiring has been 
completed, you should check that the wires 
have been connected properly: 
1.  Connect machine to power source and 
press the start button.  
2.  The sanding disc and belt should move in 
accordance with the arrow directions on the 
machine. If the movement is backward, stop 
the machine and disconnect machine 
from power. 
 
3.  Switch any two of the three wires at "R,S,T". 
 
Grounding Instructions 
This machine must be grounded. In the event of 
a malfunction or breakdown, grounding provides 
a path of least resistance for electric current to 
reduce the risk of electric shock.  
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded.  
Repair or replace a damaged or worn cord 
immediately. 
 
 
Figure 12 
(Three Phase model only) 
 
Extension Cords 
An extension cord is not recommended; if 
possible, position your Sander within reach of 
the power supply. If an extension cord becomes 
necessary, make sure the cord rating is suitable 
for the amperage listed on the machine’s motor 
plate. An undersize cord will cause a drop in line 
voltage resulting in loss of power and 
overheating. 
Use the chart in Figure 12a as a general guide 
in choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
Recommended Gauges (AWG) of Extension Cords 
Extension Cord Length *  
Amps 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
5  16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended. 
Figure 12a