Spectra HL700 Dépliant

Pagina di 2
A) HL700 is in the laser beam and the 
power is on:
Press any switch to return to normal 
operation.
The current elevation read-
ing will be held. A flashing 
display will confirm the 
reading has been captured
.
1 x quick
B) HL700 is out of the laser beam and 
power is on:
A short intermittent 
beep (The beeper 
will turn on to Low if 
turned off.)
+
1.
Press any switch to return to normal 
operation.
2. Place the HL700 in the beam. (Example: 
Fasten it to a measuring rod, bring the 
HL700 into the laser beam. You now have 
5 seconds to plumb the rod and get the 
reading captured.)
The beeper will 
chirp rapidly after 
approximately 5 
seconds to confirm 
beam capture. A flashing 
display will also indicate 
the reading has been 
captured
.
+
1 x quick
Special Menu Functions
SENS
 
Sensitivity Medium*-HighLow
AVG
 
Averaging algorithm Medium*High - Low
D.R.O
.  Numeric display ON*-OFF-.1mm
UNIT
 
Units of measure MM*-CM-IN-FRAC-FT
FRC.R
.  Fractional Reduction ON*-OFF
ARRW
  Arrow Display DB*(deadband)-PR (prop.)
O.O.B.
  Out-of-Beam Display ON*-OFF
GRD.A
.  Grade Alarm ON-OFF*
A.S.O
.  Automatic shutoff 0.5h*-24h-OFF
TX.O.L
.  Transmitter Out-of-Level OFF*RPS
TX.O.B
.  Transmitter Low Battery OFF*-RPS
INFO
 
Information about the Laserometer
(for 2 Sec., then SENS)
Press switches  
together for 2 sec
.
1. Scrolling up or down.
 
How to change Menu functions:
2. Enter Change mode.
3. Change selected items
.
4. Confirm change
.
5. To Exit.
or
+
Change special Menu Functions only in the 
case of special job requirements!
Automatic Shutoff
A.S.O. (Automatic Shut Off): 
0.5 - After 30 Minutes*
OF - Off (Unit is permanently on.)
24 - 24 hour shutoff.
Out-of-Beam Display 
O.O.B. (Out-of-Beam Display): 
Sequence to show direction to get back in 
the laser beam ( for 25 s)
ON - Out-of-Beam Display ON* 
OF - Out-of-Beam Display OFF
Grade Alarm 
GRD.A. (GradAlarm): 
When turned ON, disables the audible 
signal when on-grade. When moved out 
of the on-grade deadband, the beeper 
activates as normal:
ON - Alarm on (Solid beeper OFF)
OF - Alarm off (Solid beeper ON)*
* Default setting
For more information about special Menu 
Function contact the manu-facturer, 
importer or your local dealer
.
Sensitivity of reception
SENS (Sensitivity): 
Selects reception sensitivity to laser and 
other light sources.
MD - Medium*: for most applications.
HI -   High: When laser beam is 
 
weak, or at very long distances.
LO -  Low: If outside sources are 
 
disturbing elevation readings
.
Action
Display
Remarks
Initialization:
1. Test of LCD, LED and beeper
2. CAL: Calibration (3 sec.)
3. Unit is ready for use.
(Do not power up the unit in a laser beam 
or strobe. If detected, the unit will display 
“E200” and revert to the previous
calibration.)
The selected unit of measure determines 
the displayed deadband (accuracy).
The current accuracy is stored in memory 
and will be retained when the unit is turned 
off or when batteries are replaced.
The current beeper 
volume is stored in 
memory and will be 
retained when the unit is 
turned off or when bat-
teries are replaced.
The current unit of measure is stored in 
memory and will be retained when the unit 
is turned off or when batteries are replaced.
The current brightness of LEDs 
is stored in memory and will 
be retained when the unit is 
turned off or when batteries are 
replaced.
Action
Display
Remarks
Accuracy in mm:
0.5   1.0    2.0   5.0  10.0
Beeper 
Loud
Beeper 
Medium
Beeper 
Low
(No symbol)
mm - cm - in - frac - ft
 
LEDs 
Bright
LEDs  
Dim
LEDs 
OFF
(No symbol)
1
2
3
Turn power ON/OFF
Press and hold for 2 seconds to turn 
power OFF.
Press once to display current setting;
push again to scroll through options.
Press together to cycle the selection
.
+
Press once to display current setting, 
additional pushes to scroll through options.
Select accuracy
Select beeper volume
Select units of measure
Select brightness of LEDs
CAPTURE Function
Press once to change current setting
(A beep confirms the selected volume.)
Beeper 
Off