Because  of  the  high  amperage  draw  from  this 
machine, we do not recommend the use of exten-
sion cords. Instead, position your equipment near 
installed  wiring  to  eliminate  the  need  for  exten-
sion cords.
Extension Cords
In  the  event  of  an  electrical  short,  grounding 
reduces the risk of electric shock. The grounding 
wire in the power cord must be properly connect-
ed to the grounding prong on the plug; likewise, 
the outlet must be properly installed and ground-
ed.  All  electrical  connections  must  be  made  in 
accordance with local codes and ordinances.
Improper connections of the electrical-grounding 
conductor  increases  the  risk  of  electric  shock. 
Check  with  a  qualified  electrician  or  one  of  our 
service  personnel  if  you  do  not  understand 
the  grounding  instructions,  or  if  you  doubt  the 
machine is properly grounded.
Grounding
Electrocution or fire could 
result  if  this  machine  is 
not  grounded  correctly 
or  if  your  electrical  con-
figuration  does  not  com-
ply  with  local  and  state 
codes. Ensure compliance 
by  checking  with  a  quali-
fied electrician!
The  Model  G0450  can  be  rewired  for  440V 
operation. This rewiring job consists of replacing 
the existing control panel box with a 440V control 
panel box and rewiring the motor.
The  440V  conversion  kit  can  be  purchased  as 
#P0450253 by calling (800) 523-4777.
This procedure takes moderate electrical skill and 
the rewiring job must be inspected by a qualified 
electrician before connecting to power. 
To  rewire  the  Model  G0450  for  440V  opera-
tion:
1.  Disconnect  the  saw  from  the  power 
source!
2.  Rewire  both  motors  according  to  the  dia-
grams  on  the  inside  of  the  junction  box 
cover.  
 
 
Note:  These  drawings  are  also  shown  in 
Figure 55 for your reference, but always use 
the  drawings  in  the  junction  box  cover,  as 
they will reflect any changes to the machine 
since the time of writing.
3.  Open  the  electrical  panel  and  familiarize 
yourself with 
Figures 54 & 56 for component 
locations.
4.  Keeping  track  of  the  wire  locations,  discon-
nect all power and motor wires, so the con-
trol panel box can be completely removed.
5.  Remove  and  replace  the  control  panel  box 
with the box from the 440V conversion kit.
6.  Connect  the  power  and  motor  wires  to  the 
new  control  panel  box  in  the  same  manner 
that they were removed from the old box.
7.  Have the wiring job inspected by a qualified 
electrician.
Rewiring to 440V