Symptom
Possible Cause
Possible Solution
Machine  has  vibration  or 
noisy operation.
1.  Motor or component is loose.
2.  V-belts are worn or loose.
3.  Motor fan is rubbing on fan cover.
4.  Pulley is loose.
5.  Machine is incorrectly mounted to the floor.
6.  Cast iron motor mount is at fault.
7.  Motor bearings are at fault.
1.  Inspect  for  stripped/damaged  bolts/nuts, 
replace/re-tighten with thread locking fluid.
2.  Inspect  belts,  replace  and  re-tension  (see 
Pages 27 & 30).
3.  Replace dented fan cover/damaged fan.
4.  Remove  pulley,  replace  shaft,  pulley,  set-
screw, and key as required, and realign.
5.  Machine has loose anchor studs in floor, or 
is  sitting  on  uneven  floor.  Replace/tighten 
relocate as required.
6.  Using leverage and a small pry bar to inspect, 
carefully replace loose/broken mounts.
7.  Check  bearings,  replace  motor  or  bearings 
as required.
Sanding Operations
Symptom
Possible Cause
Possible Solution
Vibration when sanding.
1.  Loose drum bearings.
2.  Worn drum bearings.
1.  Tighten drum bearings.
2.  Replace drum bearings.
Grinding,  screeching,  or 
rubbing  noise  when  sand-
ing drums are powered up.
1.  Drum bushings lack sufficient oil.
2.  Drum bushings are worn and need replace-
ment.
1.  Oil the drum bushings (see 
Page 25).
2.  Replace the drum bushings.
Short V-belt lifespan.
1.  Pulleys not aligned correctly.
2.  Improperly tensioned.
1.  Align pulleys (see 
Page 31).
2.  Properly tension V-belts (see 
Page 27).
Machine  lacks  power; 
drums  stop  turning  under 
load.
1.  V-belts loose.
2.  Too much pressure on pressure plates.
1.  Tighten V-belts (see 
Page 27).
2.  Raise the pressure plates (
Page 35).
Feed belt slips under load.
1.  Feed belt is too loose.
2.  Too much load.
1.  Tension feed belt (see 
Page 32).
2.  Decrease load.
Feed  belt  tracks  to  one 
side  or  hits  the  feed  table 
mounts.
1.  Feed belt tracking is incorrect.
1.  Track  the  feed  belt  so  it  runs  straight  (see 
Page 31).
Excessive snipe. 
1.  Lack of outfeed support.
2.  Too much pressure from pressure plates.
3.  Too  much  pressure  from  the  rear  pressure 
plate.
1.  Set  up  an  outfeed  table  or  have  someone 
catch the workpiece as it comes out.
2.  Raise the pressure plates (
Page 35).
3.  Raise the rear pressure plate  (
Page 35).
Workpiece  kicks  out  of 
sander.
1.  Not  enough  pressure  from  the  pressure 
plates.
1.  Lower the pressure plates (
Page 35).
Sandpaper  tears  off  drums 
during operation.
1.  Nail/staple in workpiece.
2.  Sandpaper  not  tightened  or  fastened  cor-
rectly.
1.  Sand only clean workpieces.
2.  Install  the  sandpaper  correctly  (see 
Page 
22).
Table elevation controls are 
stiff and hard to adjust.
1.  Table lift screws are dirty or loaded with saw-
dust.
2.  Chain idler sprocket cap screws have been 
over tightened.
3.  Elevation  handle  helical  gear  is  dirty  or 
loaded with sawdust.
1.  Clean  and  re-grease  table  lift  screws  (see 
Page 26).
2.  Adjust the cap screws on the idler sprocket 
so it can spin freely.
3.  Clean  and  re-grease  the  helical  gear  (see 
Page 26).