Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine  does  not 
start  or  a  breaker 
trips.
1.  Plug/receptacle  is  at  fault  or  wired  incor-
rectly.
2.  Start capacitor is at fault (single-phase).
3.  Motor connection wired incorrectly.
4.  Thermal overload relay has tripped.
5.  Contactor  not  getting  energized/has  burnt 
contacts.
6.  Wall fuse/circuit breaker is blown/tripped.
7.  Power supply is at fault/switched OFF.
8.  Motor  ON  button  or  ON/OFF  switch  is  at 
fault.
9.  Centrifugal Switch is at fault (single-phase).
10. Wiring is open/has high resistance.
11. Motor is at fault.
12. Start delay module is at fault.
1.  Test for good contacts; correct the wiring.
2.  Test/replace if faulty.
3.  Correct motor wiring connections.
4.  Unplug  machine,  open  magnetic  switch  cover,  turn 
amperage dial on Thermal Protection Circuit Breaker 
to a higher amperage setting. 
5.  Test for power on all legs and contactor operation. 
Replace unit if faulty.
6.  Ensure correct size for machine load (refer to 
Page 
12); replace weak breaker.
7.  Ensure hot lines have correct voltage on all legs and 
main power supply is switched ON.
8.  Replace faulty ON button or ON/OFF switch.
9.  Adjust/replace the centrifugal switch if available.
10. Check  for  broken  wires  or  disconnected/corroded 
connections, and repair/replace as necessary. 
11. Test/repair/replace.
12. Adjust to correct delay; replace module.
Machine  stalls  or  is 
underpowered.
1.  Applying too much pressure to workpiece.
2.  Run capacitor is at fault (single-phase).
3.  Belt(s) slipping.
4.  Motor connection is wired incorrectly.
5.  Plug/receptacle is at fault.
6.  Motor bearings are at fault.
7.  Motor has overheated.
8.  Contactor not getting energized or has poor 
contacts.
9.  Motor is at fault.
10. Centrifugal switch is at fault (single-phase).
11. Start delay module at fault (3-phase only). 
1.  Use sharp blade, and reduce the feed rate.
2.  Test/repair/replace.
3.  Replace bad belt(s) as a matched set, align pulleys, 
and re-tension.
4.  Correct motor wiring connections.
5.  Test for good contacts; correct the wiring.
6.  Test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.
7.  Clean off motor, let cool, and reduce workload.
8.  Test for power on all legs and contactor operation. 
Replace if faulty.
9.  Test/repair/replace.
10. Adjust/replace centrifugal switch if available.