SEcTION 2: pOWER SuppLy
Availability
Before installing the machine, consider the avail-
ability and proximity of the required power supply 
circuit.  If  an  existing  circuit  does  not  meet  the 
requirements for this machine, a new circuit must 
be installed. To minimize the risk of electrocution, 
fire,  or  equipment  damage,  installation  work  and 
electrical wiring must be done by an electrican or  
qualified service personnel in accordance with all 
applicable codes and standards.
Electrocution, fire, or 
equipment damage may 
occur if machine is not 
correctly grounded and 
connected to the power 
supply.
full-Load current Rating
The  full-load  current  rating  is  the  amperage  a 
machine draws at 100% of the rated output power. 
On  machines  with  multiple  motors,  this  is  the 
amperage drawn by the largest motor or sum of all 
motors  and  electrical  devices  that  might  operate 
at one time during normal operations.
full-Load current Rating at 110v ...... 15 Amps
full-Load current Rating at 220v .... 7.5 Amps
The full-load current is not the maximum amount 
of amps that the machine will draw. If the machine 
is overloaded, it will draw additional amps beyond 
the full-load rating.
If the machine is overloaded for a sufficient length 
of time, damage, overheating, or fire may result—
especially  if  connected  to  an  undersized  circuit. 
To  reduce  the  risk  of  these  hazards,  avoid  over-
loading  the  machine  during  operation  and  make 
sure it is connected to a power supply circuit that 
meets the requirements in the following section.
For your own safety and protection of 
property, consult an electrician if you are 
unsure about wiring practices or electrical 
codes in your area.
A  power  supply  circuit  includes  all  electrical 
equipment between the breaker box or fuse panel 
in the building and the machine. The power sup-
ply circuit used for this machine must be sized to 
safely handle the full-load current drawn from the 
machine  for  an  extended  period  of  time.  (If  this 
machine  is  connected  to  a  circuit  protected  by 
fuses, use a time delay fuse marked D.)
circuit Information
Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one 
machine will be running at a time. If this machine 
will be connected to a shared circuit where mul-
tiple machines will be running at the same time, 
consult a qualified electrician to ensure that the 
circuit is properly sized for safe operation.
circuit Requirements for 220v
Nominal voltage .............................. 220v/240v
cycle ..........................................................60 hz
phase ........................................... Single-phase
power Supply circuit ......................... 15 Amps
plug/Receptacle ............................. NEMA 6-15
This  machine  can  be  converted  to  operate  on  a 
220V power supply (refer to 
Voltage Conversion 
instructions). This power supply must have a veri-
fied ground and meet the following requirements:
This  machine  is  prewired  to  operate  on  a  110V 
power supply circuit that has a verified ground and 
meets the following requirements:
circuit Requirements for 110v
Nominal voltage ...............................110v/120v
cycle ..........................................................60 hz
phase ........................................... Single-phase
power Supply circuit ......................... 15 Amps
plug/Receptacle ............................. NEMA 5-15