G0451 14" Sliding Table Saw
In  the  event  of  an  electrical  short,  grounding 
reduces  the  risk  of  electric  shock.  This  tool  is 
equipped with a power cord that has a grounding 
wire,  which  must  be  properly  connected  to  the 
grounding prong on the plug; likewise, the outlet 
must be properly installed and grounded. All elec-
trical  connections  must  be  made  in  accordance 
with local codes and ordinances.
Improper connections of the electrical-grounding 
conductor  increases  the  risk  of  electric  shock. 
Check  with  a  qualified  electrician  or  one  of  our 
service  personnel  if  you  do  not  understand 
the  grounding  instructions,  or  if  you  doubt  the 
machine is properly grounded.
Grounding
Electrocution or fire could 
result  if  this  machine  is 
not  grounded  correctly 
or  if  your  electrical  con-
figuration  does  not  com-
ply  with  local  and  state 
codes. Ensure compliance 
by  checking  with  a  quali-
fied electrician!
The Model G0451 can be rewired for 440V opera-
tion.  This  rewiring  job  consists  of  disconnecting 
the  saw  from  the  power  source,  changing  the 
connections  on  the  voltage  transformer,  chang-
ing the overload relays for the scoring motor, and 
rewiring the cutting motor and scoring motor. 
The necessary overload relay for this procedure 
can  be  purchased  by  calling  our  customer  ser-
vice number at (800) 523-4777 and ordering part 
number P04510014A.
This  procedure  takes  moderate  electrical  skill 
and the rewiring job must be inspected by a quali-
fied electrician before the saw is connected to the 
power source. Also, the motors can be accessed 
easier for rewiring if the blade is moved to 0˚ (90˚ 
to table) before beginning.
To  rewire  the  Model  G0451  for  440V  opera-
tion:
1.  Disconnect  the  saw  from  the  power 
source!
2.  Open the electrical panel and locate the volt-
age transformer shown in 
Figure 7.
Rewiring to 440V
Figure 7. Inside view of the control panel.
Scoring 
Motor Relay
Main Motor 
Relay
When  using  a  phase  converter,  the  power  from 
the  manufactured  power  leg  (sometimes  called 
the  wild  wire)  can  fluctuate.  Connect  the  manu-
factured  power  leg  to  the  S  terminal  to  prevent 
damage  to  the  transformer.  The  wire  from  the  S 
terminal  can  handle  some  fluctuation  because  it 
goes  directly  to  the  motor.  The  power  going  to 
the  R  and  T  terminals  goes  to  the  transformer 
and must be consistent to prevent damage. See 
the  phase  converter  instruction  manual  for  more 
information.
Phase Converter
Voltage 
Transformer
Electrical 
Access Panel