Symptom
Possible Cause
Possible Solution
Motor will not start, or it growls 
on start up.
1.  Emergency stop button is 
depressed. 
2.  Power supply fuse or circuit 
breaker has tripped.
3.  Thermal overload has tripped.
4.  Toggle switch is broken inside.
5.  Start capacitor is at fault.
6.  Motor fan cover is dented, stopping 
the fan from being able to spin.
7.  Motor is at fault.
1.  Rotate the button clockwise and allow it to 
pop out.
2.  Disconnect power, and inspect circuit for 
electrical shorts and repair. Replace circuit 
breaker if it is old or has tripped many times.
3.  Reset the thermal overload.
4.  Disconnect power, and use an ohmmeter to 
check switch terminals for continuity, and 
replace switch if required.
5.  Replace start capacitor.
6.  Replace motor fan cover (and fan, if 
damaged).
7.  Replace motor.
Motor  fails  to  develop  full  power 
(output  of  motor  decreases  rap-
idly  with  decrease  in  voltage  at 
motor terminals).
1.  Power  line  overloaded  with  lights, 
appliances, and other motors.
2.  Undersized  wires  or  circuits  too 
long.
3.  Blown capacitor.
1.  Reduce load on power line.
2.  Increase  wire  sizes  or  reduce  length  of  the 
circuit.
3.  Replace the capacitor.
Motor overheats.
1.  Motor overloaded.
2.  Air  circulation  through  the  motor 
restricted.
1.  Reduce load on motor.
2.  Clean out motor to provide normal air circula-
tion.
Motor  stalls  (resulting  in  blown 
fuses or tripped circuit).
1.  Short  circuit  in  motor  or  loose  con-
nections.
2.  Low voltage.
3.  Incorrect fuses or circuit breakers in 
power line.
4.  Motor overloaded.
1.  Repair  loose  or  shorted  terminals,  or  worn 
insulation on motor.
2.  Correct the low voltage conditions.
3.  Install correct fuses or circuit breakers.
4.  Reduce load on motor.
Main blade runs backwards.
1.  Two  of  the  power  wires  are 
reversed.
1.  Exchange wires R & T in the terminal box.
Blade  slows  when  cutting.  Blade 
makes a squealing noise on start-
up.
1.  V-belt loose.
2.  V-belt worn out.
1.  Tighten V-belt (
Page 49).
2.  Replace V-belt (
Page 49).
Troubleshooting
Disconnect power to the 
machine  when  perform-
ing  any  troubleshooting. 
Failure  to  do  this  may 
result in serious person-
al injury.
Troubleshooting