G0561 7" x 12" Metal-Cutting Bandsaw
Serious  personal  injury  could  occur  if  you 
connect  the  machine  to  the  power  source 
before  you  have  completed  the  setup  pro-
cess.  DO  NOT  connect  the  machine  to  the 
power source until instructed to do so.
110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The  Model  G0561  features  110/220V  motor  that 
is  prewired  for  110V  and  draws  the  following 
amps under maximum load:
Motor Draw at 110V ............................... 16 Amps
Motor Draw at 220V ................................8 Amps
Circuit Requirements
We  recommend  connecting  this  machine  to  a 
dedicated circuit with a verified ground, using the 
circuit  size  given  below.  Never  replace  a  circuit 
breaker with one of higher amperage without con-
sulting  a  qualified  electrician  to  ensure  compli-
ance with wiring codes. 
If you are unsure about 
the wiring codes in your area or you plan to 
connect your machine to a shared circuit, you 
may create a fire hazard—consult a qualified 
electrician to reduce this risk.
110V Circuit  ..........................................20 Amps
220V Circuit  ..........................................15 Amps
Figure 2. 6-15 plug and outlet.
Plug Type
The Model G0561 comes prewired with a NEMA 
5-15 plug. If you wish to rewire the motor to 220V 
you will need the following 220V plug (see 
Figure 
for an example):
220V Plug & Receptacle .............................. 6-15
The Model G0561 can be rewired to operate on a 
220V power source. The motor must be rewired 
according  to  the  wiring  diagram  on  the  motor 
label. The wiring configuration can also be found 
on the inside of the motor wire cover, as well as 
on 
Page 38. 
Wiring for 220V