Graco 312066z Manuale Utente
Repair
26
312066Z
Pump Installation
1.
Ensure locknut (G) is screwed on pump with flat
side up. Screw pump into bearing housing (M) until
pin holes align. Push pin (F) in. Pull retaining wire
clip (E) down.
side up. Screw pump into bearing housing (M) until
pin holes align. Push pin (F) in. Pull retaining wire
clip (E) down.
2.
Continue screwing pump into housing until fluid out-
let (D) is aligned with steel tube and top threads are
+/- 1/16 in. (2 mm) of bearing face (N).
let (D) is aligned with steel tube and top threads are
+/- 1/16 in. (2 mm) of bearing face (N).
3.
Tighten locknut (G) by hitting firmly with a
non-sparking hammer.
non-sparking hammer.
4.
Reconnect fluid inlet (C) and outlet (D).
5.
Go to step 13.
Steps 1-5 supply to pump B. To reconnect pump A,
proceed to step 6.
proceed to step 6.
C
D
F
E
G
M
N
1
TI3765a-1
Flat side faces up.
1
Lubricate threads with ISO
oil or grease.
oil or grease.
2
2
2
2
3
Pump top threads must be
nearly flush with bearing face
(N).
nearly flush with bearing face
(N).
3