Graco 312066z Manuale Utente

Pagina di 74
Repair 
36
312066Z
Transducers
1.
Turn main power OFF 
. Disconnect power 
supply.
2.
Relieve pressure, page 23.
3.
Refer to electrical diagrams. Motor control board is 
on right side inside cabinet.
4.
Disconnect transducer cables at board; see F
page 35. Reverse A and B connections and check if 
diagnostic code follows; see E21: No component A 
transducer
, page 12.
5.
If transducer fails test, thread cable through top of 
cabinet. Note path as cable must be replaced in 
same way.
6.
Install o-ring (820) on new transducer (806), F
IG
. 3. 
7.
Install transducer in manifold. Mark end of cable 
with tape (red=transducer A, blue=transducer B).
8.
Route cable into cabinet and thread into bundle as 
before.
9.
Connect transducer cable at board; see F
. 2, page 
35.
Electric Fan
1.
Turn main power OFF 
. Disconnect power 
supply.
2.
Relieve pressure, page 23.
3.
Check fuses (F) at left of breaker module, F
IG
. 4. 
Replace if blown. If good, continue with step 4.
4.
Refer to electrical diagrams. Disconnect fan wires 
from fuses (F).
5.
Remove fan.
6.
Install fan in reverse order.
F
IG
. 3. Transducers
TI10957a
820
806 (B Side)
801
806 (A Side)
F
IG
. 4. Fan Fuses
F
ti9884a-1