Repair 
46
312066Z
Display Module
Temperature and Pressure Displays
1.
Turn main power OFF 
. Disconnect power 
supply.
2.
Relieve pressure, page 23.
3.
Refer to electrical diagrams. 
4.
Put on static conductive wrist strap.
5.
Disconnect main display cable (20) at lower left cor-
ner of display module; see F
IG
. 11.
6.
Remove screws (509, 510) and cover (504); see 
F
IG
. 11.
7.
Disconnect cable connectors (506 and 511) from 
back of temperature display (501) or pressure dis-
play (502); see F
IG
. 11. 
8.
Disconnect ribbon cable(s) (R) from back of display; 
see F
IG
. 11.
9.
Remove nuts (508) and plate (505).
10. Disassemble display, see detail in F
IG
. 11.
11. Replace board (501a or 502a) or membrane switch 
(501b or 502b) as necessary.
12. Reassemble in reverse order, see F
IG
. 11. Apply 
medium strength thread sealant where shown. Be 
sure display cable ground wire (G) is secured 
between cable bushing and cover (504) with screws 
(512). 
Red Stop Button
1.
Turn main power OFF 
. Disconnect power 
supply.
2.
Relieve pressure, page 23.
3.
Refer to electrical diagrams. 
4.
Put on static conductive wrist strap.
5.
Remove screws (509, 510) and cover (504), F
IG
11.
6.
Disconnect button cable connectors (506) from back 
of temperature display (501) and pressure display 
(502). 
7.
Remove red stop button (506).
8.
Reassemble in reverse order. Be sure display cable 
ground wire (G) is secured between cable bushing 
and cover (504) with screws (512).
CAUTION
Before handling board, put on a static conductive wrist 
strap to protect against static discharge which can 
damage board. Follow instructions provided with wrist 
strap.
If replacing both displays, label temperature display 
cables TEMP and pressure display cables PUMP 
before disconnecting.
CAUTION
Before handling board, put on a static conductive wrist 
strap to protect against static discharge which can 
damage board. Follow instructions provided with wrist 
strap.