Lubrication
Other  than  the  lubrication  points  covered  in  this 
section, all other bearings are internally lubricated 
and  sealed  at  the  factory.  Simply  leave  them 
alone unless they need to be replaced.
One-Shot Oiler
Type ............Model T23963 or ISO 32 Equivalent
Amount .............................................. 1–2 Pumps
Lubrication Frequency ...... 4–8 Hrs. of Operation
The  one-shot  oiler  provides  lubrication  to  the 
vertical leadscrew, the cross feed ways, and the 
cross feed leadscrew.
To  use  the  one-shot  oiler,  pull  the  pump  handle 
out (see 
Figure 45) and push it back in with mod-
erate force. Move the grinding head up and down 
a few times through the full Z-axis path to distrib-
ute the oil on the leadscrew. Do the same with the 
Y-axis handwheel.
Use the sight glass to check the oil level and fill 
when needed.
Oil Sump
As the one-shot oiler sends oil to the cross feed 
ways, any excess oil will exit tubes in the rear and 
drain into a sump in the column. Check and drain 
the sump at least once a month to avoid overflow.
To drain the oil sump, use a 10mm hex wrench to 
remove the drain plug on the rear of the column 
(see 
Figure 46).
Figure 46. Location of oil sump drain plug.
Oil Sump
Drain Plug
Wipe up any spilled oil from the machine and floor 
before continuing operation.
Figure 45. One-shot oiler components.
Sight
Glass
Pump
Handle
Fill
Cap
Spilled oil left on the floor can become a 
slipping hazard. Always clean up spilled oil 
promptly.