Power Feed Controls
Refer  to 
Power Feeds on  Page  31  for  detailed 
instructions on operating the power feeds.
G.  ON/OFF Switch: Enables power to the power 
feed unit.
H.  X-Axis Speed Control Knob: Controls  the 
speed of table movement along the X-axis.
I.  Y-Axis Speed Control Knob: Controls  the 
speed of table movement along the Y-axis.
J.  Y-Axis Mode Selector Switch: Selects  the 
mode  of  operation  for  the  Y-axis—jog  (the 
“T”),  manual  (the  “hand”),  or  automatic  (the 
“table” symbol).
K.  Y-Axis Reverse Button: Reverses the direc-
tion of Y-axis table movement.
L.  X-Axis Mode Selector Switch: Selects  the 
mode  of  operation  for  the  X-axis—manual 
(the “hand”) or automatic (the “table” symbol).
Handwheels
M.  X-Axis Handwheel: Manually controls X-axis 
table movement.
N.  Y-Axis Handwheel: Manually controls Y-axis 
table  movement.  The  graduated  dial  has 
0.0005"  increments  with  one  full  revolution 
equaling 0.1000" of table travel.
O.  Coolant Valve: Controls the flow of coolant 
when coolant pump is turned 
ON.
P.  Z-Axis Handwheel: Manually controls Z-axis 
grinding  wheel  movement.  The  graduated 
dial  has  0.0002"  increments  with  one  full 
revolution equaling 0.0500" of table travel.
Figure 3. Power feed controls.
G
H
I
J
L
K
Figure 4. Handwheel controls.
P
N
M
O