Texas Instruments TMS320C6201 Manuale Utente

Pagina di 29
SPRZ153
TMS320C6201 Silicon Errata
3
Advisory 2.1.19 PMEMC: Branch from External to Internal
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.1.21 DMA:  DMA Data Block Corrupted After Start Zero Transfer Count
23
. . . . . . . . . . . . . . . . . . . . . . . . . . 
6
Silicon Revision 2.0 Known Design Exceptions to Functional Specifications
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.1
Program Fetch: Cache Modes Not Functional
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.2
Bootload: Boot from 16-Bit and 32-Bit Asynchronous ROMs Not Functional
24
. . . . . . . . . . . . . . . . . . 
Advisory 2.0.3
DMA Channel 0 Split Mode Combined With autoinitialization Performs Improper 
Reinitialization
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.4
DMA/Program Fetch: Cannot DMA into Program Memory From External
24
. . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.5
Data Access: Parallel Accesses to EMIF or Internal Peripheral Bus Location 
Sequenced Wrong
25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.7
EMIF: Reserved Fields Have Incorrect Values
25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.8
EMIF: SDRAM Refresh/DCAB Not Performed Prior to HOLD Request Being Granted
25
. . . . . . . . . 
Advisory 2.0.9
McBSP New Block Interrupt Does Not Occur for Start of Block 0
26
. . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.11 DMA/Internal Data Memory: First Load Data Corrupted When DMA in High Priority
26
. . . . . . . . . . . 
Advisory 2.0.12 McBSP: FRST Improved in 2.1 over 2.0
26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.13 McBSP: XEMPTY Stays Low When DXR Written Late
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.14 EMIF: Multiple SDRAM CE Spaces: Invalid Access After Refresh
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.18 DMA/Internal Data Memory: Conflict Data Corruption
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.19 EMIF: Data Setup Times
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Advisory 2.0.24 EMIF Extremely Rare Cases Cause an Improper Refresh Cycle to Occur
28
. . . . . . . . . . . . . . . . . . . . 
7
Documentation Support
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .