Roland VC-1 D-50 Manuale Utente

Pagina di 100
 
89
 
MIDI Implementation
 
2. Receive data
 
 
Channel Voice Messages
 
 
Note off
 
Status
2nd byte
3rd byte
8nH
kkH
vvH
9nH
kkH
00H
n = MIDI channel number:
0H - FH (ch.1 - 16)
kk = note number:
00H - 7FH (0 - 127)
vv = note off velocity:
00H - 7FH (0 - 127)
 
 
Note on
 
Status
2nd byte
3rd byte
9nH
kkH
vvH
n = MIDI channel number:
0H - FH (ch.1 - 16)
kk = note number:
00H - 7FH (0 - 127)
vv = note on velocity:
01H - 7FH (1 - 127)
 
 
Control Change
 
m
Bank Select (Controller number 0, 32)
Status
2nd byte
3rd byte
BnH
00H
mmH
BnH
20H
llH
n = MIDI channel number:
0H - FH (ch.1 - 16)
mm, ll = Bank number:
00 00H - 7F 7FH (bank.1 - bank.16384)
*
Not received when the Bank Select Switch (SYSTEM MIDI) is OFF.
*
The Patches corresponding to each Bank Select are as follows.
*
The MSB value to be transmitted can be set individually for 
*
each patch using Tx Bank Select (PATCH MIDI).
*
In this case, “0” is always output for the LSB.
 
 
Modulation (Controller number 1)
 
Status
2nd byte
3rd byte
BnH
01H
vvH
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Modulation depth:
00H - 7FH (0 - 127)
 
 
Portamento Time (Controller number 5)
 
Status
2nd byte
3rd byte
BnH
05H
vvH
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Portamento Time:
00H - 7FH (0 - 127)
 
 
Data Entry (Controller number 6, 38)
 
Status
2nd byte
3rd byte
BnH
06H
mmH
BnH
26H
llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
 
 
Volume (Controller number 7)
 
Status
2nd byte
3rd byte
BnH
07H
vvH
n = MIDI channel number:0H - FH (ch.1 - 16)
vv = Volume:
00H - 7FH (0 - 127)
 
 
Hold 1 (Controller number 64)
 
Status
2nd byte
3rd byte
BnH
40H
vvH
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Control value:
00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON
 
 
Portamento Switch (Controller number 65)
 
Status
2nd byte
3rd byte
BnH
41H
vvH
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Control value:
00H - 7FH (0 - 127)
0 - 63 = OFF, 64 - 127 = ON
 
 
RPN MSB/LSB (Controller number 100, 101)
 
Status
2nd byte
3rd byte
BnH
65H
mmH
BnH
64H
llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm = upper byte (MSB) of parameter number specified by RPN
ll = lower byte (LSB) of parameter number specified by RPN
 
BANK 
SELECT
MSB
LSB
PROGRAM 
NUMBER
BATCH 
BANK
PATCH 
NUMBER
 
087
000
001 - 064
Internal 1
11 -  88
001
001 - 064
Internal 2
11 -  88
002
001 - 064
Internal 3
11 -  88
003
001 - 064
Internal 4
11 -  88
004
001 - 064
Internal 5
11 -  88
005
001 - 064
Internal 6
11 -  88
006
001 - 064
Internal 7
11 -  88
007
001 - 064
Internal 8
11 -  88
008
001 - 064
Preset 1
11 -  88
009
001 - 064
Preset 2
11 -  88
010
001 - 064
Preset 3
11 -  88
011
001 - 064
Preset 4
11 -  88
012
001 - 064
Preset 5
11 -  88
013
001 - 064
Preset 6
11 -  88