Pioneer PX-42VP5 Manuale Utente

Pagina di 82
 
 
30 
27. PHASE Gain Data
 
Function 
The  external  control  equipment  changes  the  PHASE  gain  data  (Phase)  of  the 
plasma monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00    DATA01    DATA02    CKS 
 
DATA00 : USER PICTURE Gain Flag   
03H 
 
DATA01 : PHASE Gain Flag   
 
03H 
 
DATA02 : PHASE Gain   
 
00H : 0 
 
 
  : 
 
 
40H : +64
 
ACK 
  7FH   60H   80H   7FH   02H   DATA00    DATA01    CKS 
 
DATA00: USER PICTURE Gain Flag   
03H 
 
DATA01: PHASE Gain Flag       
 
  03H 
 
 
28. CLOCK Gain Data
   
Function 
The  external  control  equipment  changes  the  CLOCK  gain  data  (ratio  of 
frequency division) of the plasma monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00    DATA01    DATA02    CKS 
 
DATA00 : USER PICTURE Gain Flag   
03H 
 
DATA01 : CLOCK Gain Flag   
 
04H 
 
DATA02 : CLOCK Gain   
 
C0H : -64 
 
 
 
  : 
 
 
FFH : -01 
 
 
00H : 0 
 
 
01H : +01 
 
 
  : 
 
 
40H : +64 
ACK 
  7FH   60H   80H   7FH   02H   DATA00    DATA01    CKS 
 
DATA00: USER PICTURE Gain Flag   
03H 
 
DATA01: CLOCK Gain Flag       
 
  04H