Ingersoll-Rand 4575759 Manuale Utente

Pagina di 116
43
Sensor I
®
 Expert User Manual
2.  Press the Reset to power up the wrench.
3.  Move the Mode Selection switch to Setup.
4.  With the Reset button held in, use the Parameter Adjustment Knob to 
select Custom setup Mode #103. NOTE: The main display shows an inte-
ger from 0 to 9.
5.  Rotate the mode select switch to select the mode for which the tighten-
ing direction is to be changed. The display will indicate "-rit" for CW 
tightenings or "-LEF" for CCW tightenings.
6.  Press and hold the Reset button. Depress the Units key to select CW 
tightenings ("rit") or the Joint key to select CCW tightenings ("-LEF").
7.  Rotate the mode select switch back to the Setup position. With the 
Reset button held in, use the Parameter Adjustment Knob to set the 
Custom Setup Mode number below 20.
8.  Release the Reset button. The tightening direction is set for the mode 
selected in step 5 above. 
NOTE
After the first time a tightening is performed, changing the tightening
direction will increase the amount of time required to find the optimum
offset point. While the offset is being determined, the display will
show a flashing "OFFSET". The wrench is ready for use when the
flashing ceases.
RESET ADJUSTMENT (EVS-models only)
Some tightening applications do not require accurate angle measurement.
Custom Setup Mode #214 allows the user to decrease the sensitivity of reset
of the wrench at the expense of angle measurement accuracy. Angle
accuracy will depend on the elapsed time during which the wrench is moved