Bad Boy Mowers 02.9812.0001C Manuale Utente

Pagina di 102
 T
ROUBLESHOOTING
 
AND
 M
AINTENANCE
 : T
ROUBLESHOOTING
0 2. 9 8 1 2. 0 0 01 C
51
4
Other Errors
Error Code
Explanation
Solution
Temp over threshold
Temperature too high
Check fans/filters
Lamp over threshold
Lamp hours above recommended 
maximum
Change lamp
Lamp Off
Fan Error: Cannot strike lamp while 
any fan is in error state
Check fan, fan cabling
Pan/Tilt Aux Encoder Error
Auxiliary encoder value is too far from 
the main encoder value
Check auxiliary encoder and cabling/
connections
Gobo out of zero range
When zeroing gobo wheels, the 
wheel is too far away from zero to set 
the position
Move wheel closer to home position 
before zero command
DMX busy: cancel crossload
Cannot execute crossload with traffic 
on DMX line
Remove incoming DMX control for 
cross load
Data not crossload format
Data in memory is not proper format 
for crossload
Load software via computer
DMX: UART transmit error
Transmit buffer busy when trying to 
send
Remove any incoming DMX, retry
Crossload Timeout
Crossload execution took too long 
due to error
Remove any incoming DMX, retry
CAN Comm Error
Stopped receiving CAN messages 
from motion processor
Check CAN cables/connections, 
motor control board
Main Fan Error
Main fan CAN messages not 
received or fan not running properly
Check fan, fan cabling
UPE Fans Error
Upper Enclosure fans not running 
properly
Check fan, fan cabling
Pinch Fan Error
Pinch fan not running properly
Check fan, fan cabling
Stack Fan Error
One or more stack fans not running 
properly
Check fan, fan cabling