Chauvet 1-TRI IP Manuale Utente

Pagina di 28
Technical Information 
 
 
COLORado™ 1-Tri IP User Manual Rev. 01c 
 
-19- 
Troubleshooting Guide 
 
 
 
Symptom 
Cause(s) 
Action(s) 
General low light intensity 
·  Dirty lens assembly 
·  Clean the fixture regularly  
·  Misaligned lens assembly 
·  Install lens assembly properly  
A single tri color LED 
does not illuminate 
·  Faulty LED 
·  Replace the LED board 
·  Faulty LED board 
·  Replace the LED board 
A group of tri-color LEDs 
does not illuminate 
·  Faulty LED 
·  Replace the LED board 
·  Faulty LED board 
·  Replace the LED board 
·  Faulty LED driver 
·  Replace the LED driver board 
None of the LEDs are 
illuminating 
·  Faulty LED PCB 
·  Replace the LED board 
·  Faulty LED Driver PCB 
·  Replace the LED driver board 
·  Faulty main PCB 
·  Replace the Display / Main board 
Breaker/Fuse keeps 
blowing 
·  Excessive circuit load 
·  Check total load placed on the electrical circuit 
·  Short circuit along the power wires 
·  Check for a short in the electrical wiring 
Fixture does not power up 
·  No power 
·  Check for power on power outlet 
·  Loose or damaged power cord 
·  Check power cord 
·  Blown internal fuse 
·  Replace internal fuse  
·  Faulty internal power supply 
·  Replace internal power supply 
Fixture does not respond 
to DMX 
·  Wrong DMX addressing 
·  Check Control Panel and unit addressing  
·  Damaged DMX cables 
·  Check DMX cables 
·  Wrong polarity on the controller 
·  Check polarity switch settings on the controller 
·  Loose DMX cables 
·  Check cable connections 
·  Faulty DMX interface 
·  Replace Main PCB 
·  Faulty Main PCB 
·  Replace Main PCB 
DMX signal problems 
·  Non DMX cables 
·  Use only DMX compatible cables 
·  Bouncing signals 
·  Install terminator as suggested 
·  Long cable / low level signal 
·  Install an optically coupled DMX splitter right 
after fixture with strong signal  
·  Too many fixtures 
·  Install an optically coupled DMX splitter after 
unit #32 
·  Interference from AC wires 
·  Keep DMX cables separated from power cables 
or black lights 
 
 
 
 
 
 
 
If you still experience technical problems after trying the above solutions, contact 