Chauvet LED-RAIN36 Manuale Utente

Pagina di 13
 
 
 
 
 
 
 
LED-RAIN36 User Manual 
 
2006-07-14/15:25 
Optional Hanging Clamp 
S
ETUP
 
Power 
 
Warning! 
Verify that the power indicator label on your unit matches the line voltage applied. 
All fixtures must be connected to circuits with a suitable Earth Ground.  
 
  To determine the power requirements for a particular fixture, see the label affixed to the back plate 
of the fixture or refer to the fixture
s specifications chart.  
  A fixture
s listed current rating is its average current draw under normal conditions.  
  All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat 
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% 
to 100% switch.  
  Before applying power to a fixture, check that the source voltage matches the fixture
requirement.  
  All fixtures must be connected to circuits with a suitable Earth Ground.  
Po w e r   C a b l e   C o n f i g u r a t i o n  
C
ABLE
 
P
IN
 
I
NTERNATIONAL
 
B
ROWN
 
Live 
B
LUE
 
Neutral 
Y
ELLOW
/G
REEN
 
Earth 
EG (Ground) 
Mounting 
O r i e n t a t i o n  
This fixture can be mounted on a truss using a clamp in any position. 
R i g g i n g  
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.  
1.  Align the clamp screw with the center hole on the yoke and tighten. 
2.  Verify the structure can hold 10 times the weight of all to-be installed fixtures. 
3.  Adjust the angle on the yoke arm as necessary.