Chauvet DMX512 Manuale Utente

Pagina di 32
 
COLORdash
™ Par 
 
User Manual  
15
 
9/4/2008 12:09 PM
 
MENU 
UP 
DOWN 
ENTER 
Setting the DMX address 
Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for 
control begins to read the data on the channel indicated by the start address. For example, a fixture 
that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would 
read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the 
channels used do not overlap and note the start address selected for future reference. The 
COLORado™ Panel uses up to 9 channels of DMX.  If this is your first time using DMX, we 
recommend reading the DMX Primer in the Appendix Section. 
Control Panel Functions 
All fixture functions and settings are accessible via the built-in control panel interface. 
B
UTTON
 
F
UNCTION
 
MENU 
Exits from the current menu or function 
ENTER  
Enables the currently displayed menu or sets the currently selected value in to the 
selected function  
UP 
Navigates upwards through the menu list and increases the numeric value when in 
a function 
DOWN  
Navigates downwards through the menu list and decreases the numeric value when 
in a function  
 
Password Menu Lockout 
 
The 
COLORdash™ PAR has a
 
password lock-out feature. This can be enabled/disabled by using the Control 
Panel.  
 
Note: This feature uses a default, non-changeable, password of up + down + up + down. After 
30 seconds of inactivity, the lockout will automatically engage once it has been enabled.