Lamp 
You will need to install a lamp prior to the initial operation of the fixture. Either three GLC or GKV 
575W halogen lamps are included.   
Warning! 
When replacing the lamp, please wait 15 minutes after powering down to allow the 
unit to cool down! Always disconnect from main power prior to lamp replacement. 
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 
with alcohol and wipe it with a lint free cloth before installation. 
L A M P   I N S T A L L A T I O N   A N D   R E P L A C E M E N T  
TFX-64CM Lamp Installation 
Note:   Align labels on lens 
cover and fixture to 
reinsert. 
1) 
Loosen the thumbscrews as illustrated in figure 
1 (3 total) located near the front of the fixture. 
2) 
Pull the lens assembly out from the fixture as 
illustrated in figure 2.  
3) 
Hold the bi-pin lamps with a napkin and pull 
top end of lamp upwards to remove from 
socket as illustrated in figure 3. 
4) 
Hold the new lamp with a lint-free cloth, and 
insert lamp downward into the socket as 
illustrated in figure 3. 
Note:  
Lens cover can only be inserted one 
way! Match up the labels on the lens 
cover and the fixture to reinsert the 
lens cover properly.  
5) 
Replace lens cover housing and tighten 
thumbscrews. 
6) 
No lamp alignment is necessary for this fixture. 
 