Maytag MGR6875ADB/Q/S/W Manuale Utente

Pagina di 69
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
©2004 Maytag Services 
16023415 
19 
 
Illustration/Component Test 
Procedure 
Results 
Control Panel Assembly 
 
 
 
Model MGR6875AD* 
Continuity is indicated as follows: 
1000 – 6600 
Ω for Cancel pad 
1000 – 10000 
Ω for All other pads 
 
 
 
 
Pad 










Lower Cancel 
Upper Cancel 
Conv Bake 
Delay 
Clock 
Favorite 
Lower Clean 
Upper Clean 
Lower Bake 
Lower Light 
Upper Keep Warm 
Upper Light 
Autoset 
Lower Keep Warm 
Conv Roast 
Upper Bake 
Timer 2 
Cook & Hold 
Upper Broil 
Timer 1 
Trace 
14 & 16
17 & 16
16 & 8 
7 & 6 
8 & 17 
7 & 14 
6 & 15 
5 & 14 
6 & 14 
8 & 14 
1 & 2 
11 & 12
4 & 15 
5 & 6 
5 & 16 
5 & 7 
5 & 15 
7 & 16 
8 & 15 
7 & 15 
7 & 17 
15 & 16
14 & 17
8 & 16 
5 & 4 
4 & 14 
4 & 7 
6 & 16 
14 & 15
4 & 16 
Measurement
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
Continuity 
 
 
 
Model MGR6775AD* Membrane and Overlay