Smeg PTSA725X3 Manuale Utente

Pagina di 16
 
 
 
Instructions for the Installer 
 
 
3.1  Clearance above and around domestic appliances 
Extract from AS5601 
 
 
 
REQUIREMENTS 
 
1
 
Overhead clearances – (Measurement A
Range hoods
 and exhaust fans shall be installed in accordance with the 
manufacturer’s instructions. However, in no case shall the clearance between the 
highest part of the 
hob 
of the cooking 
appliance
 and a 
range hood
 be less than 600 
mm or, for an overhead exhaust fan, 750 mm
 
Any other downward facing 
combustible surface
 less than 600 mm above the 
highest part of the 
hob
 shall be protected for the full width and depth of the cooking 
surface area in accordance with Clause 5.12.1.2. However, in no case shall this 
clearance to any surface be less than 450 mm