Instructions for the installer
 
 
 
6
 
2.  INSTALLATION OF THE APPLIANCE 
 
 
It is the law that all gas appliances are installed by 
authorised persons
Clearance around the cooker must comply with the requirements of  
AS5601.
 
 
2.1  Electrical connection 
 
Make sure that the power line voltage matches the specifications 
indicated on the rating plate located inside the storage compartment.  
This rating plate must never be removed. 
 
 
On the power line, install a two-pole cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 
 
 
 
The wire section on the cable must not be less 
than 2.5 mm
2
(3 x 2.5 cable), keeping in mind 
that the end to be connected to the cooker 
must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only the special 
cables available at our Service Centres. 
 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance. 
 
 
Overall dimensions: location of gas and electrical connection points (all 
measures in mm). 
 
 
 
 
 
60  
410  
60  
70