Instructions for the installer
 
 
11
5.2
Nozzle replacement and primary air adjustment
 
   
 
  Loosen screw A  and push support B  all the way. Use a double head 
wrench to remove nozzle C  and assemble the suitable one, following 
the values indicated in the tables relevant to the type of gas to use. The 
screwing torque of the nozzle should never exceed 3 Nm. Reposition 
support so that nozzle is covered perfectly. 
Move the Venturi tube D  to regulate the air flow until distance “X” is 
reached indicated in the table “Regulation of primary air” and then 
secure the tube by means of screw A. After the regulations have been 
carried out, restore the seals with sealing wax or equivalent material.
 
 
   
 
 
 
 
 
 
 
 
 
   
Burner 
 
Rated 
heating 
capacity 
 
LPG – G30/G31 2.8 kPa 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
1/100 mm 
Reduced 
flowrate
(W) 
 
Flowrate 
g/h G30 
 
Flowrate
g/h G31
 
Auxiliary 
 
1.05 
 
48 
30 (1) 
380 
 
76 
 
75 
 
Semi-rapid 
 
1.65 
 
62 
30 (1) 
380 
 
120 
 
118 
 
Rapid 
 
2.55 
 
76 
37 (2) 
750 
 
185 
 
182 
 
Rapid large 
 
3.1 
 
85 
45 
800 
 
225 
 
222 
 
Fish pan 
 
1.8 
 
65 
43 (3) 
750 
 
145 
 
143 
 
Ultra rapid 
 
3.3 
 
87 
65 
1700   
240 
 
236 
 
Internal 
 
0.8 
 
42 
26 (1) 
380 
 
58 
 
57 
 
 
Double 
crown 
 
External   
3.3 
 
87 
55 
1200   
240 
 
236 
 
 
 
 
 
 
 
 
 
 
 
 
 
(1)= 33 for appliances without flame failure device. 
(2)= 40 for appliances without flame failure device. 
(3)= 45 for appliances without flame failure device.