Fisher & Paykel OR60 Manuale Utente

Pagina di 32
11
Installation instructions 
Converting to a different gas type
This appliance is suitable for use with Natural gas or LPG gas (check the “gas type” sticker 
attached to the appliance). To convert from one gas type to another, you need to replace the 
injectors, and then adjust the minimum burning setting.
Replacing the injectors
To replace the injectors:
 
Remove pan supports and burners from the cooktop.
 
Using a spanner, remove the injector (shown in figures following) and replace it with one 
according to the gas type (see the ‘Table for the choice of injectors’).
 
Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas 
inlet connections. This label states that the gas cooktop has been converted for use with LPG 
gas / Natural gas.
Important!
 
 If the cooker is suitable for use with Natural gas and must be converted for use with LPG gas, 
before connecting to gas main remove the appliance gas regulator and replace with test point 
adaptor.
 
 If the cooker is suitable for use with LPG gas and must be converted for use with Natural gas, 
before connecting to the gas main remove the appliance test point adaptor and replace with gas 
regulator.
Notes: 
- Gas regulator and test point adaptor are supplied with the appliance (packed with conversion      
  kit)
- The burners are designed so that regulation of primary air is not required.
Injector
Figure 8 Auxiliary and semi-rapid burners
Figure 9 Triple ring wok burner
Injector