Garland MCO-GD-10E Manuale Utente

Pagina di 28
 
ELECTRONIC CONTROL FAILURE CODES 
 
The GARLAND digital control has a self-diagnostic program.  If a problem occurs within the digital controller, you may 
see one of the "F" codes. 
 
Below is a listing of the "F" codes with explanations: 
 
-F1- 
Relay output is enabled when not cooking.  If this failure code appears in the display, the cook relay may be on 
even if the control is not cooking.  The control should be replaced. 
 
-F2- 
Over temperature alarm.  If this failure code appears in the display the control is sensing an oven temperature 
50° or more above the maximum set temperature (500°).   This failure may be caused by a faulty sensor. 
 
 
 
Check the sensor connection for loose wires. 
 
Replace the sensor and check for proper operation. 
 
If failure continues replace the control. 
 
-F3-
 
Open sensor circuit.  If this failure appears in the display, the control is sensing an open circuit at the sensor 
input.  This failure is most often caused by a poor connection or broken sensor. 
 
 
Check  sensor  connection  and  leads  for  broken  wires  of  loose  connections.    Replace  sensor  and  check  for 
proper operation.  If failure continues replace control. 
 
-F4- 
Shorted sensor circuit.  If this failure appears in the display, the control is sensing a short circuit at the sensor 
input.  This failure is most often caused by loose wires at the connection of shorted sensor leads. 
 
 
Check sensor connection and leads for loose wires.  Replace sensor and check for proper operation.  If failure 
continues replace control. 
 
-F5- 
Relay  outputs  not  enabled  when  cooking.    If  this  failure  appears  in  the  display  the  control  cannot  turn  the 
relays on even when cooking.  The control should be replaced. 
 
-F6- 
No 60 Hz input.  The control does not sense the input power.  This failure mode is most often the result of a 
failed component in the control.  However, this failure may also be the result of a very noisy power line.  Look 
for  any  large  electrical  noise  producing  machinery  (such  as  mixers,  compressors,  dishwashers  etc.).    If 
possible, turn these machines off.  Reapply power to the oven.  If the failure repeats, replace the control.  If 
the failure does not repeat, an electronic control may not work in this application because of noise.  You must 
isolate the supply circuit. 
 
-F7- 
The control has detected that calculated EEPROM check sum is not the same as the expected check sum 
retrieved from the EEPROM.  When the control detects this error code, it will disable outputs before the alarm 
sounds. 
 
RESISTANCE vs. TEMPERATURE CHART FOR INTERNAL OVEN TEMPERATURE SENSOR 
 
The chart below will provide the Ohms at various temperatures.  This will enable you to determine if the temperature 
probe is operable. 
 
The chart is in Degrees Fahrenheit.  How to use chart, for 350
°
, read down to 300 then across to 50, answer is 
1654Ohms of resistance. 
 
TEMP 
0° 
10° 
20° 
30° 
40° 
50° 
60° 
70° 
80° 
90° 
0° 
932 
953 
974 
995 
1016 
1038 
1059 
1080 
1101 
1122 
100° 
1143 
1163 
1184 
1205 
1226 
1247 
1267 
1288 
1309 
1329 
200° 
1350 
1370 
1391 
1411 
1432 
1452 
1472 
1493 
1513 
1533 
300° 
1553 
1574 
1594 
1614 
1634 
1654 
1674 
1694 
1714 
1733 
400° 
1753 
1773 
1793 
1813 
1832 
1852 
1871 
1981 
1911 
1930 
500° 
1949 
1969 
1988 
2008 
2027 
2046 
2065 
2085 
2104 
2123 
 
ROBERTSHAW COM6000 CONTROLLER