TROUBLE-SHOOTING 
GUIDE
The following pages contain trouble-shooting charts designed to aid an experienced serviceman in 
diagnosing any operating problems that may be experienced. In order to gain maximum benefit 
from the charts, please note:
1.
Start at the beginning of the chart and supply the appropriate answer to each question.
2.
Do not skip any section, unless instructed to do so. You may miss the solution to your prob-
lem.
3.
Evaluate the possible problem causes in the sequence in which they are presented. In gen-
eral, they began with the most likely and/or easiest to check, and proceed to the less likely 
and/or more complicated.
4.
If, after checking all indicated causes, the problem is not resolved, it is recommended that you 
try a second time. Evaluate symptoms carefully and modify your answers as necessary.
5.
If you are unable to resolve a problem after several attempts, contact customer service de-
partment at (1-800-238-3600) for assistance.
PROBLEM
PROBABLE CAUSE
REMEDY
Totally Inoperative
 No power to dispenser due 
to tripped circuit 
breaker.
 Reset circuit breaker. Confirm that 
breaker is correct size and no 
other equipment is operating on 
the same circuit. Also confirm 
that supply voltage is +10% of 
nameplate specifications.
 Loose or broken power sup-
ply connection inside 
dispenser.
 
 Repair connection
 
No cooling
 Line voltage is not within 
+10% of nameplate 
specifications causing 
compressor overload to 
trip
 Contact an electrician
 Both thermostats in OFF 
position
 Turn ON thermostats and recali-
brate the temperatures to 34
o
-40
 o
F (1.1
 o
C –4.5
 o
C).
 Defective compressor over-
load or start capacitor
 Replace