Cornelius 29677 Manuale Utente

Pagina di 3
620914101
December 9, 1998
Rev A
E
IMI Cornelius Inc; 1998
IMI CORNELIUS INC
One Cornelius Place
Anoka MN 55303--6234
Telephone (800) 238--3600
Facsimile (612) 422--3246
FOR
ED2XX DUAL-MOUNTING KIT
DISPENSER MODEL
KIT PART NUMBER
ED200/250
629085101
PARTS LIST
Item
No.
Part No.
Name
Qty.
1
629080214
Insulated Lower Panel, Dual
1
2
29677
Rear Mounting Plate
1
3
620023904
Front Mounting Plate (For 6 and 8 Beverage Valve Units)
1
4
32990
Wire Connectors
4
5
50904
RTV Sealant, 3--oz Tube
2
6
620013301
Drip Tray Cover, Black
1
7
620500201
Gasket
150-In
8
620914101
Installation Instructions
1
9
70555
Screw, No. 8-32 By 1 5/16-In. long
2
10
71010
Captivating Plastic Washer, No. 8
2
11
91486
Cornelius Logo
1
1. Disconnect electric power to the Ice/Beverage Units while installing the Kit.
2. Remove lower panel assembly from both Units.
3. Relocate beverage valve keyswitch to right side of the beverage panel on one of the Units. This Unit will be
positioned on the right side of the counter.
A. Remove beverage panel access covers.
B. Locate black and red wires of the keyswitch. Cut these wires approximately 2-inches from the crimp
nut connection to the yellow wires.
C. Loosen the keyswitch mounting nut and remove the keyswitch. Using a 7/8-inch deep socket will help
access the nut.
D. Remove plastic plug from right side of the beverage panel and insert into the left side keyswitch
opening.
E. Install keyswitch into the right side of the beverage panel and tighten mounting nut.