Chapter 3: Installation 
39 of 102 
 
Blender Calibration 
The load cells on the Auger blender are FACTORY CALIBRATED. Since the load cells can be 
subject to shock loading during shipping, moving, etc., we recommend that they be recalibrated. 
The heart of the Auger blending system is the load cell with the supply calibration weight. They 
monitor the weight off each ingredient added to the blender weigh hopper. Since load cells are 
reading the actual material weight that is metered by the feeders, the proper calibration of these 
load cells is essential for the correct operation of the blender
. This calibration must be performed 
upon initial installation and startup of the blender. They should also be checked once a month with 
a calibration weight and, if necessary, recalibrated to ensure that they have not been damaged 
in the normal routine of removing and replacing the weigh hopper for cleaning, color changes, 
etc.
 
The calibration of each load cell is accomplished by using two reference points on the output of the 
load cell scale. The first of these points is known as the “Tare Weight.” This is the weight of the 
empty hopper assembly on the load cell. This is also known as the zero weight point (starting point) 
of the scale. This zero or starting point must be initialized with an empty weigh hopper. There must 
be no binding or leverage put on the load cell. 
The second weight point used in the load cell calibration procedure is a known amount of weight for 
the weigh hopper. A calibration weight is provided with all Slide Gate/Auger blending systems. The 
calibration weight is stamped with its actual weight on top. If this is not available, any object with a 
known weight accurate to the nearest 1/100th of a pound, in the 2 - 10 lb. range, proportional to your 
size blender, will suffice. (The weight should be as close as possible to the maximum batch size you 
plan to run).  The weight will be in pounds, unless the blender is set up for metric operation. In the 
case of a metric blender display, the weight to be used is calibrated in kilograms. 
Given the two weight points on the load cell scale, the controller should determine any other weight 
on the load cell span. This is limited to the maximum capacity of the load cell. The standard load cell 
used on these blenders has a span accuracy of 
1
/
10  
%. 
The maximum capacity of each load cell is clearly marked on top of the load cell. This value will be 
indicated in kilograms (1 kg = 2.2 lbs.). 
Weigh Hopper (Load Cell) Calibration 
(Recommended only if the calibration is out of spec) 
1.  From the “Recipe” Page, touch the Manufacturer’s icon and enter “5413,” then press the 
“Enter˝ key. 
2.  Touch “Calibration” and then “Scale Calibration.” 
Note:   It is not necessary to calibrate the weight scale on a brand new blender; 
however, it is recommended that the calibration be checked periodically to 
ensure that the reported inventory totals are accurate.  Remember that in most 
cases a bad calibration is worse than no calibration.