Mitsubishi Electronics 882.00207.00 Manuale Utente

Pagina di 103
882.00207.00 
Chapter 7: Appendix 
91 of 102 
 
 
Alarm Setup 
This screen allows the user to configure the feeder type for each feeder; configure whether a feeder 
will retry during the metering of a batch, and enable or disable the “Out of Material” alarm for any 
feeder.  If a hopper is set to “No Retry” then the blender will continue to meter the rest of the batch 
even if this hopper runs out of material.  No “Out of Material” alarm will be given regardless of how 
the alarm is configured unless the user has purchased and wired in the low level proximity switches 
in each hopper.  To configure each hopper, perform the following steps: 
1.  Select a feeder by touching the “Select Feeder” box. 
2.  The current settings for that hopper will be shown. 
3.  Make the necessary adjustments and select a new feeder to configure if desired. 
4.  Press “Done” to exit. 
 
Typical Alarm Flags & Feeder Setup Screen 
 
Alarm Log  
This screen shows the last 100 stored alarms.  The log can be viewed, printed and cleared. 
 
 
 
  Typical 
Alarm 
Log 
Screen 
 
Clear Alarm 
Log 
Print Alarm 
Log 
Alarm Log 
Go back to 
Setup 
Directory 
Scroll Through 
Alarm Log 
Select a Feeder to 
Configure 
Change the Alarm 
Silence Delay 
Enable or Disable 
Retries 
Enable or Disable 
Alarms 
Go back to Setup 
Directory