GROUNDING 
INSTRUCTIONS
This stove is for use on 120 volts. The cord has a 
plug as shown in Figure 2. An adapter is available 
for connecting three-blade grounding-type plugs 
to two-slot receptacles. The green grounding lug 
extending from the adapter must be connected to 
a permanent ground such as a properly grounded 
outlet box. The adapter should not be used if a 
three-slot grounded receptacle is available.
Figure 2 - Grounding Methods
Figure 3 - Electric Stove Control Panel
OPERATING 
INSTRUCTIONS
Once the unit has been properly connected to a 
ground electrical outlet, it is ready to operate.
Note:
 Ensure the circuit breakers for power 
supply are turned on. 
CONTROL PANEL OPERATION
Controls are located on the back of the unit near 
the top (see Figure 3).
1.  Main ON/OFF power switch: This switch is 
located at the furthest right corner on the 
control panel when looking at the back of 
the unit. Turn the switch to ON and unit 
will be ready to operate. The "|" indicates 
ON and "O" indicates OFF. 
2.  Flame  ON/OFF  Switch: This  switch  is 
located in the middle between the Main 
ON/OFF switch and the Heater ON/OFF 
switch on the control panel when looking at 
the back of the unit. Turn the switch to ON 
and the flame effect will turn on. The "|" 
indicates ON and the "O" indicates OFF.
3.  Heater  ON/OFF  Switch: This  switch  is 
located to the left of the Flame ON/OFF 
switch on the control panel. It has a symbol 
of the sun directly below it.
4.  Thermostat Control Dial: This dial is located 
at the furthest left corner on the control panel. 
It has a symbol of a thermostat directly below 
it. Turn the dial clockwise past the number 8. 
Built-In 
Thermostat
Main Power 
Switch
Flame Switch
Heater Switch
Grounding Pin
Adapter
You should hear a small clicking sound indicat-
ing the heater has started and heat will emit 
from the vents at the top of the unit from the 
front. To turn off heater, turn the dial counter 
clockwise past number 1 and turn the Heater 
Switch to OFF position. To increase the desired 
temperature, turn the dial clockwise towards 
Number 9.
CLEANING AND 
MAINTENANCE
  WARNING: Always  discon-
nect power and allow the heater 
to  cool  before  performing  any 
cleaning, maintenance or reloca-
tion of this heater. Turn controls 
to  OFF  and  remove  plug  from 
outlet or turn off circuit breaker 
to heater.
Turn off heater and circuit breaker to heater before 
performing any cleaning and/or maintenance. Al-
low heater to cool completely.
BULB REPLACEMENT
 WARNING: The halogen light 
bulbs  in  your  unit  can  become 
extremely hot. Allow at least 10 
minutes between turning off the 
heater  and  removing  the  light 
bulbs to avoid accidental burns.
There are a total of 4 ( halogen light bulbs (type 
GX6.35 rated 120 volts, 35 watts) in your unit.
•  1 bulbs provide illumination for the ember bed 
beneath the log set 
•  1  bulbs  provide  illumination  for  the  flame 
generation assembly
•  2 bulbs for replacement