Powerex MPD1508 Manuale Utente

Pagina di 27
Tank
Drain moisture
Daily
2500
Inlet air filter
Replace
(Every 2,500 hrs or less)
Blower fan
Clean
Fan Duct
Clean
Compressor Fins
Clean
(Every 2,500 hrs or less)
Bearings
Replace
Compression rings Replace
Wrist pin bearing
Regrease
Piston set
Replace
V-belt
Inspect, replace
*Note 3
Safety valve
Confirm operation
(Every 2,500 hrs or less)
Pressure gauge
Inspect
(Every 2,500 hrs or less)
Air leaks
Inspect
Filters
Replace
▲ (View delta pressure
indication)
Moisture drains
Inspect
traps
Suction pressure
(refrigerated)
Heat exchanger
Medical Package System
COMPRESSOR MAINTENANCE SCHEDULE
Operating Hours
Item
Action needed
500
2500
5000
10,000
15,000
20,000
Remarks
QUADPLEX  MPQ
TRIPLEX  MPT
DUPLEX  MPD 
DRYER  SYSTEM 
MDR  OR  MDD
FILTER SYSTEM  
MFP
 
LEFT
END
VIEW
RIGHT
END
VIEW
Consult factory 
for special voltages 
or arrangements.
32"
32"
8"
32"
5
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the cycle time and do
maintenance accordingly.
3. * The tension of the V-belt should be adjusted during the initial stage and inspected every 1,500 hours afterwards. Proper belt tension for 3/4 to 3 HP units is
12 lbs./.5” deflection; for 5 to 20 HP units, 16 lbs./1.5” deflection
● Inspect     ▲   Replace
+
+
facing the black fan shroud and
counterclockwise if facing the
compressor flywheel.)
c. Set both selector switches to the
auto position.  Compressors will
both run until the lead pressure
switch closes.
d. Open valve at the air receiver
leading to Medical Air System.
e. Check for air leaks at the
connections.
9. Check that the compressor operates
without excessive vibration, unusual
noises or leaks.
10. Check the discharge pressure. Also
make sure the air pressure rises to the
designated pressure setting by
checking the discharge pressure
gauge.
11. Check the operation of the pressure
switch or the pilot valve for
continuous run units by opening
the stop valve and confirming the
compressor starts or reloads as
pressure drops.