Middleby Marshall Kit 39733 Manuale Utente

Pagina di 8
Qty.
P/N
Description
1
39732
Instructions
1
34982
Watlow high limit control module
1
30693
Reset switch w/ lighted pushbutton
1
35634
Mounting bracket, reset switch
1
35691
Wire set, reset switch (includes 4
wires and 3 1/4”/25mm connectors)
1
33812-1
Thermocouple, type J, 6”/152.4mm
1
39690
Mounting sleeve, thermocouple
Instructions for Service Kit 39733
High Limit Conversion Kit for PS300, 310, 350, & 360 Ovens
Middleby Cooking Systems Group  •  1400 Toastmaster Drive  •  Elgin, IL 60120  •  USA  •  (847) 741-3300  •  FAX (847) 741-4406
TOOLS REQUIRED
•
Drill with 3/16” drill bit
•
Middleby Marshall Thermocouple Signal Source
Generator (P/N 27170-0192)
•
Wire cutters/strippers
Qty.
P/N
Description
2 ft./610mm 27152-0050 Wire, #18 AWG, brown
2 ft./610mm 27152-0053 Wire, #18 AWG, white
2 ft./610mm 27152-0054 Wire, #18 AWG, purple
8
1455A8750
Wire connector, 1/4”/6.4mm
1
3002693
Wire tie, nylon
2
2000076
Screw, 6-32 X 1-5/8”
2
1421B8803 Screw, 6-32 X 1/4”
4
2001327
Nut, 6-32
KIT COMPONENTS - 
Check that the kit includes ALL of these parts BEFORE you begin!
A. OVERVIEW
This Service Kit is used to replace two different types of
United Electric high limit/cooldown controllers with a
Watlow high limit controller for PS300, 310, 350, and
360 Ovens.  See Figure 1.
•
The early (Type 54) United Electric control was ONLY
equipped with a high limit circuit.  Ovens equipped
with this control did NOT have a cooldown circuit.
This control was used on the following models:
-
PS300/350 Gas (early)
-
PS300/310/350/360 Electric (early - all voltages)
For these ovens, the kit directly replaces the Type
54 high limit control with the Watlow high limit con-
trol.
•
The later (Type 55) United Electric control was
equipped with BOTH high limit and cooldown circuits,
and was used on the following models:
-
PS300/310/350/360 Electric (late), 208/240V and
480V UL versions ONLY
For these ovens, the kit replaces the Type 55 con-
trol with the Watlow high limit control, and uses the
oven’s temperature controller to provide the
cooldown circuit.
Figure 1
Page 1 of 8
P/N 39732
Rev. B • V1 • 5/99
United Electric Type 54
High Limit Control
United Electric Type 55
High Limit/Cooldown
Control
Watlow High
Limit Control
Lighted Reset