Dacor MOV Manuale Utente

Pagina di 20
9
Planning the Installation
Installation Instructions
Electrical Specifications
 IMPORtANt
•  Preheat times and cavity temperature recovery times 
will be increased slightly if operating on less than a 
240 Vac circuit.
•  This appliance is provided with electrical connection 
leads in a flexible metal conduit. These leads may be 
a smaller gage than the standard household wiring of 
the dedicated supply circuit, but they are suitable for 
connection to these circuits under the jurisdiction of 
the National Electric Code, and/or the local inspection 
authority.
•  Locate the junction box so that the wiring may be dis-
connected without removing the oven from the wall.
It is the owner’s responsibility to ensure that a qualified 
electrician performs the electrical connection of this appli-
ance. The electrical installation, including minimum supply 
wire size, must comply with the National Electric Code 
ANSI/NFPA 70 (latest revision) and local codes and ordi-
nances.
A copy of this standard may be obtained from:
National Fire Protection Association  
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be sup-
plied to the appliance from a dedicated, grounded, single 
phase circuit that is protected by a properly sized circuit 
breaker or time-delay fuse. If a time-delay fuse is utilized, 
fuse both sides of the line (L1 and L2).
Model type Dedicated Circuit 
Requirements
total  
Connected Load
Single 27”
240 Vac 60 Hz.,  
4 wire*, 30 Amp. 
dedicated
4.6 kW (19.5 Amp.)
Single 30”
Double 27”
240 Vac 60 Hz.,  
4 wire*, 50 Amp. 
dedicated
9.25 kW (38.9 Amp.)
Double 30”
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above electrical ratings are for reference only. For the 
exact ratings see the product data plate. See page 3 for 
location.
Verify that all the parts are included. If any item is missing 
or damaged, please contact your dealer immediately. Also 
make certain that you have all tools and parts necessary to 
ensure a proper installation before proceeding.
•  Exhaust deflector
◊  27” defector - PN 46050B 
or
◊  30” deflector - PN 46051B
•  Mounting and exhaust deflector screw kit
◊  Single oven screw kit - four (4) 3/4” mounting 
screws, four (4) 1 1/4” mounting screws and three 
(3) exhaust deflector screws - PN 700486-1 
or
◊  Double oven screw kit - Six (6) 3/4” mounting 
screws, six (6) 1 1/4” mounting screws and three 
(3) exhaust deflector screws - PN 700486-2
•  Meat probe, one (1) - PN 72723
•  Broiler grill and pan - PN 12157
Parts List
•  Standard oven racks two (2) for a single oven, five (5) 
for a double oven
◊  27” standard rack - PN 72747 
or
◊  30” standard rack - PN 72713
•  GlideRack™ oven rack, one (1)
◊  27” GlideRack™ oven rack - PN 72948 
or
◊  30” GlideRack™ oven rack - PN 72949
•  Stainless steel cleaner - stainless steel models only 
PN A302
•  Product literature