Dacor MOV Manuale Utente

Pagina di 20
6
Planning the Installation
Selecting the Location
•  Carefully check the location where the oven is to be 
installed. The oven should be placed for convenient 
access, but away from drafts that may be caused by 
doors, windows, and heating, ventilation and air condi-
tioning outlets.
•  Make certain that electrical power can be provided in 
the selected location. Be certain that proper clearance 
is provided for the oven door when it is in the open 
position.
Cabinet Cutout
•  Plan the installation so that all minimum clearances are 
met or exceeded. Cutout dimensions shown provide 
minimum clearances, unless otherwise noted.
•  The specified minimum cabinet depth and width must 
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
•  Cabinet cutout dimensions must be used as indicated.
A
B
4“ typical toe kick (shown)
3/4” (1.9 cm)
support platform
Recommended
electrical 
location
9 5/8” (24.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm) min.
clear to 
bottom of
door
C
C
A
B
4“ typical toe kick (shown)
Alternate
electrical 
location
3/4” (1.9 cm)
support platform
Recommended
electrical 
location
31 1/4” (79.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm) 
min. clear to
bottom
of door
Model 
Number
A
B
C
EO127
27” 7/16” 
(69.7 cm)
25 ½”  
(64.8 cm)
27”  
(68.6 cm)
56 ½”  
(143.5 cm)
MOH127
MOV127
EO130
28 ½” 
(72.4 cm)
30”
(76.2 cm)
62 ½”
(158.8 cm)
MOH130
MOV130
EO227
50 9/16”
(128.4 cm)
25 ½”  
(64.8 cm)
27”  
(68.6 cm)
NA
MOH227
MOV227
EO230
28 ½” 
(72.4 cm)
30”
(76.2 cm)
MOH230
MOV230
Single Wall 
Oven Cutout
Double Wall 
Oven Cutout
Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.