National Instruments 321645c-01 Manuale Utente
Chapter 2
Function Reference — Line_Change_Attribute
©
National Instruments Corporation
2-277
NI-DAQ FRM for PC Compatibles
Line_Change_Attribute
Format
status = Line_Change_Attribute (deviceNumber, lineNum, attribID, attribValue)
Purpose
Sets various options on an I/O connector and internal lines (6602 devices only).
Parameters
Input
Parameter Discussion
Legal ranges for the lineNum, attribID and attribValue parameters are in terms of constants
defined in a header file. The header file you should use depends on the language you are
using:
defined in a header file. The header file you should use depends on the language you are
using:
•
C programmers—
NIDAQCNS.H
(
DATAACQ.H
for LabWindows/CVI)
•
BASIC programmers—
NIDAQCNS.INC
(Visual Basic for Windows programmers should
section in Chapter 1,
, for more information.)
•
Pascal programmers—
NIDAQCNS.PAS
lineNum indicates which line you want to change the attributes of. Legal values for this
parameter are
parameter are
ND_PFI_0
through
ND_PFI_39
,
ND_RTSI_0
through
ND_RTSI_6
, and
ND_RTSI_CLOCK
.
attribID indicates which feature you are interested in changing. Legal values are listed in the
following paragraphs, along with the corresponding values you can expect for attribValue.
following paragraphs, along with the corresponding values you can expect for attribValue.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
lineNum
u32
name of the line you want to set properties of
attribID
u32
identification of the attribute you want to change
attribValue
u32
value of the attribute specified by attribID