Delta Electronics SIG80 Manuale Utente

Pagina di 4
                                                                                                                   
Page 3.
MODELS SIG
80
 / SIG
80
M / SIG
110
 / SIG
110
D / SIG
110
H
 
3.  Connect wiring   
3-1. Follow all local electrical and safety codes 
3-2. NEVER place a switch where it can be reached from a tub
 or shower
 
3-3. Connect wires as shown in wiring diagrams.
 
Single Speed Models: SIG80, SIG110 
Motion Model: SIG80M 
OFF
ON
L
N
POWER SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
GREEN
GRD
 
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
 
Humidity Model: SIG110H  
Dual Speed Model: SIG110D  
HI
POWER SWITCH
MODE SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
WHITE
BLUE
GREEN
GRD
L
N
L
N
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WIRING
PLATE
BLACK
WHITE
GROUND
(bare)
BLUE
MODE
SWITCH
POWER
SWITCH
 
3-4. Using wire nuts (not provided), connect the house power 
cable to the ventilating fan wires.
 
is the smallest conductor that shall be used 
for branch-circuit wiring.
 
4.  Grille attachment   
4-1. Insert the motion sensor unit into the grille (Fig. G) (only for 
SIG80M)
4-2. Insert the mounting springs into the slots and mount the grille 
to the body. (Fig. H)
 
Celling
Sensor unit
Grille
 
Fig. G 
Slots
Spring
 
Fig. H 
5.
  Operation   
Delay time control
(SIG80M & SIG110D)
or Humidity preset control
(SIG110H).
SIG110H
SIG110D
SIG80M
Low speed air volume
preset control (SIG80M,
SIG110H, SIG110D).
control options
 
Single Models: SIG80, SIG110 
5-1. Single speed control mode: Turn the POWER switch on to 
operate at single speed mode the LED indicator will be green.
 
3-5. 14 AWG (2.1 mm2)