1. Disconnect power.
2. Use UL listed wire connectors and connect white wires  
  (A) together.
3. Use UL listed wire connectors and connect black wires  
  (B) together. 
 
WARNING
Fire Hazard
Electrically ground the blower. Use copper wire.
Connect ground wire to green ground screw in  
terminal box. Failure to do so can result in death, 
fire, or electrical shock.
4. Connect green (or bare) ground wire from power supply  
  to green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6. 
Install the 50W maximum halogen light bulb. See  
  “Replacing the halogen lamp” in the “Range Hood  
 
  Care” section.
7. Reconnect power. 
 
Complete Installation
Replace the two bottom panels.
Replace grease filter if removed. See the “Range Hood  
  Care” section.
Check the operation of the range hood fan and light.    
  See “Range Hood Use” section.
If range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
Disconnect power and check wiring connections. 
  
NOTE
To get the most efficient use from your new 
range hood, read the “Range Hood Use” section.
1.
.
.
  
NOTE
Do not reconnect power until the installation is 
complete.
Before starting the installation, remove the 
grease filter, left and right side panels
Complete installation to reinstall the side panels.
 
Remove the screw from the  
  terminal box cover.  
  Remove terminal box cover  
  and set aside. 
 
 
 
Remove the power supply knockout from the top 
  or rear of the vent hood (depending on the incoming 
  location of your home power supply cable) and  
  install a UL listed or CSA approved ½” strain relief. 
 
 
 
 
 
 
 
 
Using 2 or more people, lift the hood into final position. 
  Feed enough electrical wire through the ½” UL listed  
  or CSA approved strain relief to make connections in  
  the terminal box. Tighten the strain relief screws.
Position the range hood so that the large end of 
  the keyhole slots are over the mounting screws. 
  Then push the hood toward the wall so that the screws  
  are in the neck of the slots. Tighten the mounting screws,  
  making sure the screws are in the narrow neck of slots.
Connect ventwork to hood. Seal joints with vent  
  clamps or duct tape to make secure and airtight.
Check that back draft dampers work properly. 
 
 
MAKE ELECTRICAL CONNECTION
 
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
.
.
4.
.
.
.
A. Power supply  
     knockout
A
A. Terminal box cover
B. Screw
A
B
INSTALLING THE HOOD
A
B
C
D
E
F
G
A.White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable
F. UL listed or CSA approved
½” strain relief
G. Green ground screw